| Sign In | Join Free | My futurenowinc.com | 
              
  | 
      
Brand Name : HCATM
Model Number : GMF603-A
Certification : ExdIICT3/FM/CSA/ATEX
Place of Origin : Xi'an
MOQ : 1
Price : $1000USD/pieces
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 100000 pieces per month
Delivery Time : 3-5 days
Packaging Details : Packed in cardboard or wooden cases
Model : GMF603-A
Acuracy : ±1.0%
Medium : Gas/Steam/Liquid
GMF603-A Multi-parameter vortex flow meter

Features
High sensitivity, low gas flow rate up to 2m/s
 The range ratio exceeds the traditional vortex street and the measurement flow rate range is wide
 Patented double vortex sensor design for excellent vibration resistance
 No moving parts, no pressure loss
 Built-in temperature and pressure sensor dynamically monitor fluid temperature and pressure
 Direct measurement of steam mass flow without external temperature pressure compensation
 Fully isolated electrical structure completely filters out external interference
 Wide supply voltage input range for a variety of complex power environments
 Support temperature and pressure compensation integrated two-wire system 4 ~ 20mA power supply
 Large screen LCD double-line display, clear and easy to read
 With Modbus and HART@4~20mA Fieldbus interface
Application
Compressed air standard consumption measurement
 Steam mass flow and consumption measurement
 Natural gas standard flow and consumption measurement
 Coal mine gas drainage flow monitoring
 Fluid temperature pressure measurement
Technical parameters
| Model | GMF603-A | 
| Medium | Gas/Steam/Liquid | 
| Nominal Diameter | DN15~300 mm (1/2 ~ 12 inches) | 
| Flow Range |  			 Gas/Steam: DN15, DN20: 6m/s~70m/s; DN25, DN32: 4m/s~70m/s; DN40 ~ DN300: 2m/s to 70m/s Liquid: 0.3m/s~7m/s  |  		
| Accuracy |  			 Working condition flow: ±1.0% RD (gas/steam); Mass flow: ±1.5% RD; Medium pressure: ±0.5% FS Medium temperature: ±1.0 °C (±1.0% FS >100 °C)  |  		
| Repeatability | ±0.3RD% | 
| Output | 4~20mA@HART, RS-485, Bluetooth, Internet of Things | 
| Power | 13.5 ~ 42VDC | 
| Medium Temperature | -40~150 ° C (normal temperature type); -40~ 250 ° C (high temperature type) | 
| Process Pressure | 1.6MPa (universal) 2.5MPa, 4.0MPa (optional) | 
| Process Temperature | -40~+85°C | 
| Environment Humidity | 5~100% RH | 
| Process Connection | Clamp type / flange connection type / clamp connection (sanitary) type | 
| Protection Level | IEC IP65/IP67 | 
| Explosion-proof Grade | ExdIICT3/FM/CSA/ATEX | 
| Material |  			 Body: 304 or 316L   			Vortex sensor: 316L   			Temperature sensor: 304   			Pressure sensor: 316L   			Converter housing: aluminum  			 |  		

| 
                                             | 
                